Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat element login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.
Uncover better diagnostic information and facts through extended watch on the anatomical construction on all convex probes.
probe. The picture abnormality may very well be attributable to Swap the probe, or the swivel in the 4D probe or perhaps the 4D push replace the 4D drive board board.
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
The DP-fifty Skilled is surely an impressive, high-functionality Ultrasound Method engineered to assist you to have the insights you require. The Procedure’s potent motor and substantial-speed processing deliver excellent image excellent and a whole information management Answer.
5.2.three Geometric positioning accuracy Longitudinal geometric positioning accuracy Exam Step: Do changes as the way in which in testing the maximum depth. Document the gap by 20mm Every single section about the longitudinal targets line using the measurement caliper; Decide on the value with the greatest error (to 20mm), estimate the accuracy using the formulation beneath The measurement caliper needs to be positioned with the upper fringe of the focus on, Take note:... Web site seventy nine Transverse geometric positioning accuracy Check Step: Cover the scan area with the phantom with h2o or few gel, gently Get in touch with the probe With all the scan surface Regulate the depth, making the transverse targets for being displayed within the graphic. Alter the focus place for being posited beside the transverse targets (the normal is not really crystal clear) Modify parameters like attain, TGC, generating Every transverse targets being clearly shown. Site 80 5.5.two.four Blackout Region Take a look at Step: Protect the scan area on the phantom with h2o or couple gel, gently Get hold of the probe Using the scan floor Modify the depth at a decreased benefit, and set the focus at the nearest spot to the scan Dp50rb login surface area. Lower the worth of parameters like AP, Attain till the track record noise just is often found. Web page 81: Computer software Update And Upkeep
NOTE: About the keep an eye on, the brightness adjustment will come ahead of distinction. Immediately after readjusting the observe’s distinction and brightness, change all preset and peripheral options.
Cookies are essential to the proper functioning of the web-site. To increase your knowledge, we use cookies to remember log-in details and provide protected log-in, accumulate figures to improve internet site functionality, and produce material tailor-made to the interests.
The chapter materials the method to confirm primary functionality and functionality of item. This is often only utilized for reference, not preventive execution. Functionality checking and testing of this section shall be carried out by Mindray provider engineers and the user jointly. Page 66: Basic Examination
NOTE: Ahead of uploading the log, ensure the ultrasound procedure continues to be connected to network, in any other case, the process may alert “couldn't hook up with server” The server (smtp.
Function: On the back again-stop of the principle board, a special check IC is made use of to observe signal voltages and clock battery energy which have been provided to the principle board by the leading device box electricity source module.
Be aware: Be sure that you can pull out and thrust in to the IO board sockets vertically when pulling out and assembling the IO board assembly on the placement from the cope with. Eliminate panhead screws with washers M3X6 (four) utilized to secure the IO board, and afterwards you may acquire out the IO board. Web page 116 Clear away panhead screws with washers (2 M3X6) which might be preset on the main unit, just take out the higher baffle and then pull out two cables connecting the principle board to the facility module assembly.
Page one hundred forty five Cleanse control panel Applications: dry smooth fabric, gentle soapy water Process: Use dry comfortable fabric to clean the floor on the procedure. If the technique is dirty, moisten the smooth fabric with gentle soapy h2o and wipe off any stains. Use dry soft cloth to get rid of any moisture and allow all really hard surfaces to totally air-dry. Site 146: Thoroughly clean The Peripherals
Material System Check the battery periodically : a) Check out if battery can be charged Typically when electric power-on: That The existing potential is a hundred% or capacity raises soon after a brief time implies which the battery can be billed normally.